Blue Asia Labs - Services de test, d'inspection et de certification

Blog

C-V2X RSU & OBU Certification: How to Plan OmniAir, FCC and CE in Parallel

Your C-V2X RSU or OBU may be technically ready—but is it ready for the U.S. or European market?

For intelligent transportation and connected-road projects, manufacturers often face three different requirements at the same time:

FCC. CE/RED. OmniAir Certification.

They are sometimes treated as three versions of the same certification.

They are not.

FCC and CE/RED address regulatory market access. OmniAir addresses C-V2X interoperability and industry certification.

Understanding this difference early can prevent duplicated testing, wrong test configurations and unexpected delays when an RSU or OBU moves from engineering validation to commercial deployment.

1. First: What Does Each Certification Actually Prove?

Think of the compliance strategy as three layers.

Layer 1 — Regulatory Compliance

For the United States, the product must satisfy applicable FCC requirements for its radio operation and intended deployment.

For Europe, the equipment may fall under the Radio Equipment Directive (RED) 2014/53/EU, together with applicable harmonised standards and other relevant EU requirements.

These are regulatory market-access obligations.

Layer 2 — C-V2X Interoperability

This is where OmniAir Certification becomes important.

OmniAir provides independent third-party certification for C-V2X RSUs, OBUs and modules, with testing covering interoperability, conformance, security and performance.

An OmniAir certificate should therefore not be described as a replacement for FCC or CE.

It answers a different question:

Can this V2X device reliably operate and interoperate within the expected connected-vehicle ecosystem?

Layer 3 — Deployment and Customer Requirements

Transportation agencies, infrastructure operators and automotive OEMs may impose additional technical requirements.

In some projects, an OmniAir-certified device may be strongly preferred—or explicitly requested in procurement specifications.

OmniAir notes that its certification can support eligibility for procurements requiring certified products.

So the commercial requirement may be stricter than the basic legal requirement.


2. The U.S. C-V2X Path Has Changed

This is particularly important for manufacturers targeting the United States.

The FCC adopted new rules in November 2024 to transition U.S. 5.9 GHz ITS operations from DSRC toward C-V2X, and the final C-V2X technical rules became effective on February 11, 2025.

This means an American C-V2X product strategy should no longer be based simply on older DSRC assumptions.

For an RSU or OBU, the engineering team should establish early:

  • Operating frequency range

  • Channel bandwidth

  • Transmit power

  • Antenna configuration

  • PC5/C-V2X implementation

  • RF exposure considerations where applicable

  • Emissions performance

  • Software and firmware configuration

  • Intended FCC authorization route

The key point is that the U.S. radio configuration must be frozen before formal testing.

A later change in power, antenna, frequency configuration or RF hardware can affect the regulatory assessment.


3. Europe Uses a Different Regulatory Logic

Europe has its own C-ITS spectrum and technical framework.

The EU harmonised the 5 875–5 935 MHz band for safety-related ITS applications. The current framework also provides specific conditions for road ITS use in different parts of the band.

For C-V2X products, ETSI has developed dedicated technical specifications.

For example:

ETSI EN 303 613 defines the LTE-V2X access layer for ITS operating in the 5 GHz band.

The newer ETSI EN 303 798 extends this framework to LTE-V2X and NR-V2X, including 5G-based V2X technology.

This creates an important difference from the U.S. approach.

A product cannot simply take its U.S. C-V2X configuration, change the label and assume it is ready for Europe.

The manufacturer needs to review:

Frequency + channelisation + RF parameters + harmonised standards + RED assessment + market configuration.


4. Europe Is Also Moving Toward Wider C-V2X Channels

There is another development manufacturers should watch closely.

In July 2026, the European Commission adopted Implementing Decision (EU) 2026/1800, amending the 5.9 GHz ITS spectrum framework to introduce wider frequency channels for safety-related road ITS applications.

The decision supports the introduction of 20 MHz channels in part of the 5.9 GHz range, alongside existing 10 MHz channel arrangements.

For future C-V2X product platforms, this is important because RF architecture decisions made today may need to support more than one channel configuration.

Manufacturers should therefore avoid designing the RF front end around a single deployment scenario without checking the target market's roadmap.


5. OmniAir Is Not Just Another RF Test

This is one of the most important points for product managers.

An RF laboratory can determine whether the device meets specified radio parameters.

OmniAir goes further into the connected-vehicle communication ecosystem.

Current OmniAir C-V2X certification programs cover:

  • RSUs

  • OBUs

  • C-V2X modules

  • Communication protocols

  • Message handling

  • Interoperability

  • Security services

  • Performance

  • Relevant V2X test cases

The certification framework references technologies and standards such as 3GPP LTE-V2X, SAE J2735, SAE J3161, IEEE 1609.2 and IEEE 1609.3, depending on the device and certification scope.

This is why a product can pass its RF regulatory testing and still require additional interoperability work before OmniAir certification.


6. RSU and OBU Should Not Be Planned the Same Way

Although both devices use C-V2X, their integration environments are different.

RSU

The RSU is installed in roadside infrastructure.

Engineering teams need to consider:

  • Pole/cabinet installation

  • Outdoor environmental conditions

  • Antenna and cable configuration

  • Ethernet/network interfaces

  • GNSS timing

  • Power supply

  • Traffic signal interfaces

  • NTCIP or project-specific interfaces

  • Security and remote management

OmniAir specifically positions RSU certification around interoperability with certified OBUs and other connected-vehicle infrastructure.

OBU

The OBU is installed in the vehicle.

The critical factors become:

  • Vehicle power supply

  • Antenna position

  • Vehicle grounding

  • CAN/Ethernet interfaces

  • GNSS

  • Vehicle data

  • EMC environment

  • Vehicle-level integration

  • Software and application behaviour

Therefore, one C-V2X radio platform does not automatically mean one identical certification strategy for RSU and OBU.


7. The Biggest Mistake: Testing Too Early With the Wrong Configuration

A typical project may look like this:

Prototype → FCC test → CE test → OmniAir test → Customer deployment

The problem is that the configuration may change between each stage.

For example:

Engineering antenna → FCC antenna → EU antenna → customer antenna

or:

Firmware V1.0 → FCC V1.2 → OmniAir V1.5 → production V2.0

Every change creates a potential compliance question.

For C-V2X products, we recommend establishing a Configuration Control Matrix covering:

  • Hardware version

  • RF chipset

  • PA/LNA

  • Antenna

  • Cable

  • Frequency

  • Channel bandwidth

  • Transmit power

  • Firmware

  • Protocol stack

  • Security software

  • GNSS

  • Interfaces

  • Country/region configuration

This matrix should be established before formal testing begins.


8. A Better Parallel Certification Strategy

Instead of treating FCC, CE and OmniAir as three independent projects, manufacturers can plan them in parallel.

Phase 1 — Architecture Review

Define:

U.S. configuration + EU configuration + OmniAir target profile

before PCB and RF hardware are frozen.

Phase 2 — RF Pre-Compliance

Validate:

  • Output power

  • Occupied bandwidth

  • Spurious emissions

  • Receiver performance

  • Antenna matching

  • EMC

  • GNSS coexistence

Phase 3 — Regulatory Testing

Prepare the applicable:

FCC + RED/CE

test programme according to the final market configuration.

Phase 4 — OmniAir Pre-Validation

Use the target OmniAir certification scope to identify interoperability and protocol gaps before formal certification.

OmniAir recommends Plugfest participation as a way to validate interoperability before conformance certification testing.

Phase 5 — Final Certification and Deployment

Only after hardware, firmware, RF configuration and protocol behaviour are controlled should the final certification package be locked.


9. What Should C-V2X Manufacturers Ask Before Starting?

Before requesting a quotation, answer these questions:

1. Is the product an RSU, OBU or module?

2. Which countries will the product be deployed in?

3. Which C-V2X release and frequency configuration are required?

4. Is FCC authorization required for the intended U.S. deployment?

5. Which RED harmonised standards apply to the European configuration?

6. Does the customer or transportation agency require OmniAir Certification?

7. Will the same antenna and firmware be used for all markets?

8. Does the product require additional EMC, cybersecurity or environmental testing?

These answers determine the real certification scope.

Build the Certification Roadmap Before the RSU/OBU Is Frozen

For intelligent transportation projects, the most efficient strategy is not:

FCC → CE → OmniAir → redesign

It is:

Market requirements → RF architecture → regulatory gap assessment → pre-test → FCC/CE testing → OmniAir validation → certification → deployment

At BlueAsia Labs, we support connected mobility and IoT products through integrated RF, EMC, wireless, Bluetooth, IoT and automotive compliance testing.

For C-V2X RSU, OBU and module manufacturers, our team can help map the U.S. and European requirements at the beginning of the project and identify where FCC, CE/RED and OmniAir testing can be coordinated rather than duplicated.

The earlier the certification architecture is defined, the less likely a V2X product is to reach final testing with the wrong RF configuration or an unexpected interoperability gap.



SHARE

Rédigé par

king.guo

Ingénieurs d'essai accrédités CNAS partageant leur expérience terrain en RF, CEM et certification internationale.

Demander un devis

Service en ligne

[email protected] 4000259520 8613534225140
Accueil Ligne directe Mobile E-mail
Haut
Contactez-nous
We use cookies to improve your online experience. By continuing to browse this website, you agree to our use of cookies.

Cookies

About Cookies

Cookies are small text files stored on your device when you visit a website. Blue Asia Labs uses cookies to remember your language preference, keep forms secure and understand how visitors use our pages.

Cookies We Use

Strictly necessary — language selection and form security. These cannot be disabled.
Performance — anonymous visit statistics that help us improve the site.

We do not use advertising or tracking cookies. You can block or delete cookies in your browser settings at any time; some features may not work as expected.

Contact

Questions about this policy? Email [email protected].